Read the unified stored timeline of PDU event alerts, CMP device-connection observations, and custom-function action results. This reads event_logs history rather than the seven-day event_state snapshot view. Use explicit since/before bounds to select the desired time range. Timestamps filter by deviceTs, while sortBy may select deviceTs or receivedAt. Rows can retain their historical identity after a PDU event definition is deleted. Device name and connectionState are current presentation data, not a reconstruction of their historical values.
Requires a CMP session bearer token or active personal access token. Results are limited to the caller's accessible PDUs under the existing viewEventInfo device/group-role rules. PDUs excluded by those rules are omitted rather than producing a per-device forbidden error; an empty visible scope returns an empty result.